MET ONE 6000
MET ONE 6000 공기 입자 계수기는 연속 입자 모니터링을위한 ISO 21501 정확도를 제공하는 제약, 반도체, 하드 디스크 드라이브 및 평면 패널 디스플레이 산업 내 청정실 환경의 특정 요구 사항을 충족하는 유연한 크기, 유량 및 통신 옵션을 갖춘 컴팩트 한 디자인입니다. MET ONE 6000 원격 공기 입자 계수기의 통합 다중 매개 변수 측정으로 초기 설치 비용 절감.
Specifications
Light source : Long Life Laser™ diode
Weight : 0.68 kg (1.5 lb)
Dimensions (W x D x H) :
13.56 cm x 8.13 cm x 10.87 cm (5.34 in. x 3.20 in. x 4.28 in.) (refer to Figure 1)
Enclosure : 304 stainless steel
Status indicator :
Multi-colored LED for normal status, count alarm, count alert, sensor failure, flow failure or communication failure
Power requirements : 9–28 VDC (source: Class 2 limited energy, < 150 VA)
Power consumption, maximum :
Serial and pulse units: 3.3 W; Ethernet unit: 4.3 W
Operating temperature : 10 to 32 °C (50 to 90 °F)
Storage temperature : –40 to 70 °C (–40 to 158 °F)
Operating humidity : 5 to 95% relative humidity, non-condensing
Storage humidity : 5 to 98% relative humidity, non-condensing
Port sizes
Model 6002: barb fitting for 0.32 cm (1/8-inch) ID inlet tubing, 0.64 cm (¼-inch) ID
outlet tubing
Model 6003: barb fitting for 0.32 cm (1/8-inch) ID inlet tubing, 0.64 cm (¼-inch) ID
outlet tubing
Model 6015: barb fitting for 0.64 cm (¼-inch) ID inlet tubing, 0.64 cm (¼-inch) ID
outlet tubing
Signal output options
Pulse
Analog 4–20 mA
Serial RS232 with Modbus RTU or FXB communication protocol (no networking)
Serial RS485 with Modbus RTU or FXB communication protocol
Ethernet with ModbusTCP protocol
Data storage : 1000 samples/records
Number of size channels :
Standard 2CH, optional 4CH (exception—pulse units have 2 channels only)
Flow rate
Model 6002 : 0.1 cfm (2.83 Lpm)
Model 6003 : 0.1 cfm (2.83 Lpm)
Model 6015 : 1.0 cfm (28.3 Lpm)
Sensitivity
Model 6002 : 0.2 μm at 0.1 cfm (2.83 Lpm)
Model 6003 : 0.3 μm at 0.1 cfm (2.83 Lpm)
Model 6015 : 0.5 μm at 1.0 cfm (28.3 Lpm)
Range
Model 6002 : 0.2 μm to 5.0 μm at 0.1 cfm (2.83 Lpm)
Model 6003 : 0.3 μm to 10.0 μm at 0.1 cfm (2.83 Lpm)
Model 6015 : 0.5 μm to 10.0 μm at 1.0 cfm (28.3 Lpm)
Flow control ; Through critical orifice
Inlet pressure : Ambient to 2.5 mm (0.1 in) Hg vacuum
Vacuum requirements : At least 406 mm (16 in.) Hg
Counting efficiency
Model 6002: 50% at 0.2 μm (per JIS and ISO)
Model 6003: 50% at 0.3 μm (per JIS and ISO)
Model 6015: 50% at 0.5 μm (per JIS and ISO)
* 전화주문 : 031-704-2401 팩스주문 : 031-704-2421 메일주문 : aaa@a-a.co.kr
입금계좌 : 국민은행 298737-04-004838 예금주 :아이에스테크주식회사
*카드결제는 홈페이지 상에서 지원되지 않습니다. 카드결제를 이용하실 분들은 031-704-2401로 연락 바랍니다.
- 배송료 : 10만원 미만시 착불 발송 됩니다.
배송여건이 어려운 섬지방의 경우와 제품의 무게등 배송상의 문제로 인해 배송비용은 추가 될 수 있습니다.
- 퀵서비스 요청시 착불 배송이 원칙 입니다.
- 택배 마감 시간은 오후 4시 입니다.
- 물품 파손 및 기능상의 이상이 있을경우 즉시 당사로 연락하여 사고 접수 바랍니다.
- 재고품목의 단순 변심 및 사양변경에 따른 경우 왕복 배송비가 부담 됩니다.
- 수입발주품 및 주문제작품은 반품 및 교환이 원천 불가 하오니 주문시 충분한 사양 검토 바랍니다.