Model 9103


If you've been using dry-well calibrators for field work, you know there's a lot more to a dry-well than its temperature range and stability. Size, weight, speed, convenience, and software are also significant. Field dry-wells need to be portable, flexible, and suitable for high-volume calibrations or certifications.

The three models of Hart Scientific field dry-well temperature calibrators beat every other comparable dry-well in the industry in performance, size, weight, convenience, ease of calibration, software, and price. In addition, the heating and cooling rate of each of these dry-wells is adjustable from the front panel. The thermal switches can be checked for actuation testing, and multiple-hole inserts are available for a variety of probe sizes.

Hart Scientific field dry-well temperature calibrators are easy to calibrate. You don't even have to open the case. This means fewer maintenance costs and less down time when these Hart dry-wells do need calibration. Every Hart Scientific dry-well temperature calibrator has been tested and comes with a NIST-traceable calibration.

Hart Scientific's Interface-it software lets you adjust set-points and ramp rates, log dry-well readings to a file, create an electronic strip chart, and perform thermal switch testing with data collection. The software is written for Windows and has a great graphical interface.

Hart Scientific Model 9103 Dry-Well Temperature Calibrator

The Hart Scientific Model 9103 dry-well temperature calibrator covers temperatures up to 50°C below ambient, so –25°C is reached under normal ambient conditions. The Hart Scientific 9103 dry-well is stable to ±0.02°C, and its display is calibrated to an accuracy of ±0.25°C at all temperatures within its range. In just eight minutes, 0°C is reached, and 100°C is reached in six minutes. Your time is spent calibrating - not waiting.

Choose one of four removable inserts sized for probes from 1/16 inch to 1/2 inch in diameter:

  • Insert A handles a full range of probe sizes with a single well of each size.
  • Insert B features two wells each of 3/8, 1/4, and 3/16 inches in diameter for doing comparison calibrations.
  • Insert C has six 1/4-inch-diameter wells for multiple probe calibrations.
  • Insert D has three pairs of metric sized wells.
Hart Scientific Model 9140 Dry-Well Temperature Calibrator

The Hart Scientific Model 9140 dry-well temperature calibrator has a temperature range of 35°C to 350°C, and it reaches its maximum temperature in just 12 minutes. At six pounds, it's small enough to easily carry in one hand. The Hart Scientific Model 9140 is truly a unique innovation in dry-wells.

The Hart Scientific Model 9140 dry-well temperature calibrator has a stability of ±0.05°C or better and a uniformity of at least 0.4°C in the largest-diameter wells and 0.1°C in the smaller wells. Despite its small size, this unit performs.

Use the display, calibrated to ±0.5°C, as your reference, or use an external thermometer for maximum calibration accuracy. With three removable inserts to choose from, the Hart Scientific Model 9140 dry-well temperature calibrator is as versatile as it is fast.

Hart Scientific Model 9141 Dry-Well Temperature Calibrator

The Hart Scientific Model 9141 dry-well temperature calibrator is an upright unit that does calibrations up to 650°C. It weighs only eight pounds and heats up to 650°C in only 12 minutes. This dry-well does everything that larger and more costly dry-wells are capable of doing.

The four-inch-wide Hart Scientific Model 9141 dry-well temperature calibrator is amazing. You can control all functions from the front panel or hook it up to your PC with its built-in RS-232 port.

The Hart Scientific Model 9141 dry-well temperature calibrator has three removable well inserts available, an optional carrying case, a NIST-traceable calibration, and the best price in the industry.






Quick Specs

  • Manufactured by Fluke / Hart Scientific
  • Temperature range from -25°C to 650°C
  • Accuracy to ±0.25°C
  • Stability to ±0.02°C
  • Uniformity to ±0.1°C
  • RS-232 and Interface-it software included
  • Easy to recalibrate
  • 124mm immersion depth

* 전화주문 : 031-704-2401 팩스주문 : 031-704-2421 메일주문 : aaa@a-a.co.kr

  입금계좌 : 국민은행 298737-04-004838  예금주 :아이에스테크주식회사


*카드결제는 홈페이지 상에서 지원되지 않습니다. 카드결제를 이용하실 분들은 031-704-2401로 연락 바랍니다.
 
     

DELIVERY

  • 배송 방법 : 택배 & 화물
  • 배송 지역 : 전국지역
  • 배송 비용 : 4,000원
  • 배송 기간 : 3일 ~ 7일
  • 배송 안내 :

    - 배송료 : 10만원 미만시 착불 발송 됩니다.

      배송여건이 어려운 섬지방의 경우와 제품의 무게등 배송상의 문제로 인해 배송비용은 추가 될 수 있습니다.

    - 퀵서비스 요청시 착불 배송이 원칙 입니다.

    - 택배 마감 시간은 오후 4시 입니다.

EXCHANGE INFO

- 물품 파손 및 기능상의 이상이 있을경우 즉시 당사로 연락하여 사고 접수 바랍니다.


- 재고품목의 단순 변심 및 사양변경에 따른 경우 왕복 배송비가 부담 됩니다.


- 수입발주품 및 주문제작품은 반품 및 교환이 원천 불가 하오니 주문시 충분한 사양 검토 바랍니다.

SERVICE INFO

A/S 서비스 신청은 신청서 다운로드 후 내용작성 후 동봉하여 발송 바랍니다.

게시물이 없습니다

글쓰기 목록

게시물이 없습니다

글쓰기 목록

HOME  COMPANY  AGREEMNET  PRIVACY  GUIDE

298737-04-004838

국민은행 / 아이에스테크주식회사

       

저희 쇼핑몰은 KG이니시스를 통해 안전거래를 위해
현금 등으로 결제시 구매안전서비스를 이용하실 수 있습니다